Compact, Space-Saving Design
Fits into limited equipment space or close to the point of use.
Heat Gas and Water Instantaneously with Clean Methods
We have a wealth of practical applications
Rapid, clean heatingof gases and water
Superheated Steam Generation & Compact High-Efficiency Heat Exchange

HEAT BEAM CYLINDER™ B2 Type
WaterSuperheated steam
A compact superheated steam generator that vaporizes water and superheats the steam in a single heating section.
Uses: Material drying, food heating and microbial inactivation, and heat treatment in low-oxygen environments
Water, process liquids, gasHeated liquid or gas
Install it in a pipeline as an inline liquid heater for water or process liquids, or as an inline gas heater for nitrogen and other compatible gases.
Uses: Heating gases for drying or controlled atmospheres; hot-water cleaning and rinsing; heating cleaning, plating and surface-treatment solutions
Existing steam supplySuperheated steam
Use it as a steam superheater to further heat an existing steam supply. The configuration is selected to suit the temperature, pressure and flow rate.
Uses: Food heating and drying metal or glass materials
Liquid or gasCooled liquid or gas
It can also cool liquids and gases. Discuss a cooling-side configuration suited to the fluid, temperature and flow rate.
Uses: Temperature control of water or process liquids in equipment, and cooling sample gas for analysis
Patented heat-exchange structure (schematic)
Water, gases and process liquids are heated in a flow path separate from the heater.
Fits into limited equipment space or close to the point of use.
The heater is separate from the fluid path. Gases and liquids are heated without direct contact with the heater surface.
SUS316L stainless steel is used. High-temperature versions may use heat- and oxidation-resistant SUS310S for the heat exchanger and Inconel for the piping.
Heat is efficiently transferred to water, gases and process liquids as they pass through the flow path.
Steam temperature (°C)
Heater temperature (°C)
Steam temperature (°C)
Heater temperature (°C)
Discuss HEAT BEAM CYLINDER integration,
contract development or consulting
Request product literature

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Heating and cooling gases, water and process liquids
View Details

Applications:Built-in water tank and feed pump. Operates when connected to a power supply.
View Details

Ru catalyst reaction chamber: up to 600°C
Applications:Generates hydrogen from biomethane and water
View System Configuration
The water feed rate is the flow rate of liquid water supplied to HEAT BEAM, not the volumetric flow rate of steam at the outlet. Water feed rates and maximum temperatures are guidelines for different conditions and vary with operating conditions.
2013 data
Gas temperature (°C)
Nitrogen flow rate (SLM)
Scroll horizontally to view all columns
| Nitrogen flow rate (SLM) | HB side 550°C | HB side 650°C | HB side 750°C |
|---|---|---|---|
| 10 | 347 | 409 | 488 |
| 20 | 296 | 353 | 414 |
| 30 | 252 | 305 | 357 |
| 40 | 219 | 267 | 315 |
| 50 | 198 | 241 | 278 |
| 60 | 179 | 215 | 241 |
| 70 | 162 | 200 | 210 |
| 80 | 150 | 184 | 189 |
| 90 | 141 | 172 | 174 |
| 100 | 133 | 159 | 162 |
2013 data
Gas temperature (°C)
Nitrogen flow rate (SLM)
Scroll horizontally to view all columns
| Nitrogen flow rate (SLM) | HB side 450°C | HB side 550°C | HB side 650°C | HB side 750°C |
|---|---|---|---|---|
| 10 | 358 | 427 | 519 | 576 |
| 20 | 337 | 400 | 475 | 538 |
| 30 | 313 | 365 | 437 | 500 |
| 40 | 290 | 336 | 400 | 457 |
| 50 | 271 | 317 | 373 | 426 |
| 60 | 252 | 293 | 349 | 400 |
| 70 | 235 | 271 | 319 | 371 |
| 80 | 221 | 255 | 299 | 349 |
| 90 | 211 | 243 | 282 | 333 |
| 100 | 202 | 234 | 269 | 322 |
Steam temperature (°C)
Heater temperature (°C)
Measured example for the high-temperature B2 version. Water feed rate: 30 mL/min at all three points. Detailed conditions, including temperature measurement locations and pressure, have not been confirmed.
Scroll horizontally to view all columns
| Water feed rate (mL/min) | Heater temperature (°C) | Superheated steam temperature (°C) |
|---|---|---|
| 30 | 480 | 498 |
| 30 | 460 | 244 |
| 30 | 521 | 730 |
2013 data
Gas temperature (°C)
Nitrogen flow rate (SLM)
Scroll horizontally to view all columns
| Nitrogen flow rate (SLM) | HB side 450°C | HB side 550°C | HB side 650°C | HB side 750°C |
|---|---|---|---|---|
| 10 | 485 | 578 | 658 | 736 |
| 20 | 488 | 580 | 670 | 761 |
| 30 | 482 | 570 | 660 | 750 |
| 40 | 467 | 554 | 649 | 740 |
| 50 | 451 | 543 | 632 | 721 |
| 60 | 434 | 529 | 612 | 705 |
| 70 | 417 | 515 | 592 | 687 |
| 80 | 402 | 497 | 572 | 668 |
| 90 | 389 | 485 | 557 | 652 |
| 100 | 377 | 473 | 540 | 636 |
Steam temperature (°C)
Heater temperature (°C)
The source graph states 33 mL/min water feed. The feed rate at the 1100°C point differs from another record and requires confirmation.
Scroll horizontally to view all columns
| Heater temperature (°C) | Water feed rate (mL/min) | Steam temperature (°C) | Heat exchanger temperature (°C) |
|---|---|---|---|
| 500 | 33 | 446 | 362 |
| 700 | 33 | 620 | 554 |
| 900 | 33 | 752 | 723 |
| 1000 | 33 | 806 | 809 |
| 1100 | 33 in graph (to be confirmed) | 865 | 935 |
Gas temperature (°C)
Nitrogen flow rate (SLM)
Scroll horizontally to view all columns
| Nitrogen flow rate (SLM) | Heater 600°C | Heater 800°C | Heater 1000°C | Heater 1100°C |
|---|---|---|---|---|
| 20 | 477 | 625 | 721 | 730 |
| 40 | 511 | 655 | 770 | 788 |
| 60 | 525 | 664 | 788 | 818 |
| 80 | 526 | 664 | 793 | 834 |
| 100 | 517 | 656 | 790 | 837 |
HB vaporizer 6.3 kW
Steam temperature (°C)
Heater temperature (°C)
Scroll horizontally to view all columns
| Heater temperature (°C) | Water feed 40 mL/min | Water feed 70 mL/min | Water feed 100 mL/min |
|---|---|---|---|
| 400 | 380 | ||
| 500 | 567 | 159 | |
| 600 | 689 | 507 | |
| 700 | 773 | 735 | 371 |
| 730 | 458 |
Steam temperature (°C)
Heater temperature (°C)
Scroll horizontally to view all columns
| Heater temperature (°C) | Water feed 75 mL/min | Water feed 100 mL/min | Water feed 125 mL/min | Water feed 150 mL/min |
|---|---|---|---|---|
| 700 | 565 | 454 | ||
| 800 | 672 | 599 | 406 | |
| 900 | 754 | 722 | 600 | 464 |
| 1000 | 825 | 820 | 746 | 653 |
Superheated steam temperature (°C)
Water feed rate (mL/min)
Scroll horizontally to view all columns
| Water feed rate (mL/min) | Heat exchanger side (°C) | Outlet temperature (°C) | Notes |
|---|---|---|---|
| 30 | 1150 | Approx. 930 | Value read from the graph |

Example: water supplied from an air-pressurized tank
Scroll horizontally to view the diagram.
A feed pump supplies a metered flow of water from the tank.
Nitrogen pressurizes the water in the tank, and a flow controller regulates the water feed rate.
Mains water is supplied directly through a water softener or deionizer.
Our engineers review your application and installation requirements and help with model selection and equipment integration.
We recommend a model and configuration suited to your application and requirements.
We work with you on equipment integration and water supply arrangements.
We can also arrange water tanks, feed pumps and other auxiliary equipment.
Contact us about demonstration units or equipment loans to check operation before integration.
Discuss HEAT BEAM CYLINDER integration,
contract development or consulting
Request product literature
High-temperature superheated steam,generated with gas-fired heat.
A gas burner heats the heat exchanger to generate superheated steam from water at temperatures up to 900°C. The system is intended for processes requiring larger quantities of steam.

Potential use: supplying steam for thermal decomposition of resins, or for decomposing and removing resin from composites such as CFRP.
Potential use: supplying steam to furnaces for carbonization and volume reduction, or to high-temperature processes that further break down char.
Potential use: supplying high-temperature steam to reformers that produce hydrogen or synthesis gas from methane or other feedstocks.
For firing and binder removal (debinding). We review the process conditions, including material compatibility with steam.
Using city gas (Japan: 13A) or LPG as the heat source can reduce energy costs compared with electric heating. It also reduces the need to provide a large electrical supply for heating.
Example estimate from our brochure. Actual costs vary substantially with operating hours and fuel and electricity prices. Figures are in Japanese yen.


Heated nitrogen is introduced into exhaust piping to reduce byproduct buildup.
Learn More
Superheated steam is supplied to a furnace to recover gas containing hydrogen and other components from poultry manure.
Learn More
Integrated into a system that produces hydrogen from biomethane and water.
Learn More

Experimental examples in which heated precursors form thin films on room-temperature wafers or PET.
Learn More

Superheated steam is used for drying and reducing the volume of organic materials, and for microbial inactivation in powdered foods.
Learn More
A proposed application in the heat-exchange section of a binary-cycle power system using geothermal or hot-spring heat.
Learn More

| Application | Heating and Cooling of Gases, Water, and Chemicals |
|---|---|
| Power | 120~170W, 100V single-phase |
| Connection | VCR or SWG 1/4 inch |
| Weight | 0.7kg |
| Size | 45x55x116 (mm) |

| Application | Heating and Cooling of Gases, Water, and Chemicals, Generation of Superheated Steam |
|---|---|
| Power | 370W, 100V single-phase |
| Connection | VCR or SWG 1/4 inch |
| Weight | 1.1kg |
| Size | Φ60x133 (mm) |

| Application | Heating and Cooling of Gases, Water, and Chemicals, Generation of Superheated Steam |
|---|---|
| Power | 800W, 100V/200V single-phase |
| Connection | VCR or SWG 1/4 inch or 3/8 inch |
| Weight | 1.52kg |
| Size | Φ85x147 (mm) |

| Application | Heating and Cooling of Gases, Water, and Chemicals, Generation of Superheated Steam |
|---|---|
| Power | 2.1KW, 200V single-phase |
| Connection | VCR or SWG 3/8 inch |
| Weight | About 3kg |
| Size | Φ85x217 (mm) |

| Application | Heating and Cooling of Gases, Water, and Chemicals, Generation of Superheated Steam |
|---|---|
| Power | 10.5kW, 200V, 3-phase or single-phase |
| Connection | VCR or SWG 3/8 inch |
| Weight | About 9.2kg |
| Size | Φ114x325 (mm) |

| Application | Heating and Cooling of Gases, Water, and Chemicals, Generation of Superheated Steam |
|---|---|
| Power | 6.3kW, 200V single-phase |
| Connection | VCR or SWG 3/8 inch |
| Weight | About 5.5kg |
| Size | Φ114x270 (mm) |

| Application | Heating and Cooling of Gases, Water, and Chemicals, Generation of Superheated Steam |
|---|---|
| Power | About 3kW, 200V single-phase |
| Connection | VCR or SWG Options include 3/8 inch or 1/2 inch. |
| Weight | About 7.8kg |
| Size | Φ103x406(flange is 170Φ) (mm) |
| Maximum Temperature Reached | 950°C with SiC Heater |

| Application | This system is equiped with water pump and tank, and emit super steam only by electric power connection |
|---|---|
| Power | You can choose power in range from 100W to 10kW. |
| Connection | Steam Outlet : VCR or SWG, Size Options: 1/4 inch, 3/8 inch, or 1/2 inch. |
| Weight | About 42kg |
| Size | 490x560x730 (mm) |
| Maximum Temperature Reached | ~950℃ |

| Application | H2 generator from Bio-CH4 and water (H2O) |
|---|---|
| Power | ~3KW |
| Connection | H2 output and CH4 inlet are 1/4 SWG. |
| Size | Height: 1.5m, Footprint: 0.5m□ |
| CO concentration | Below 1-ppm detection limit |
| Maximum Temperature Reached | Ru-catalyst reaction chamber ~600°C |